LITE Temperature Monitoring · USB Plug-and-Play

AnyCage Lite

Continuous, non-invasive temperature monitoring for single-cage and small-scale studies — at a starter price that fits any budget.

Temperature Activity
AnyCage Lite temperature monitoring reader mounted on a mouse home cage
Product Overview

Focused temperature monitoring, right inside the home cage

AnyCage Lite uses the UID UCT-2112 temperature-sensing microchip, the same implantable transponder trusted across UID's broader lab animal ID portfolio. These chips deliver ±0.1°C accuracy across a 30–46°C physiological range, linking every reading directly to an individual animal ID. Antennas mount magnetically or via the included clip in either a 3″ round or 2″×5″ rectangular format to fit standard cage tops and rack configurations.

AnyCage Lite is a plug-and-play USB temperature monitoring system designed for labs running single-cage studies or small cohorts. Each reader sits directly at the cage — no dedicated controllers, no server infrastructure, no IT overhead. Plug a reader into any lab workstation, open the Data Collector software, and you are logging continuous temperature data in minutes.

The system supports up to eight readers per PC, making it straightforward to scale from a pilot study of one cage to a more expansive cohort as your project grows. Each additional reader costs $300, keeping expansion affordable and incremental.

Illustration of a mouse in a home cage with the AnyCage Lite antenna mounted above
Key Capabilities

Built for simplicity. Designed for science.

Six capabilities that make AnyCage Lite the right starting point for continuous home cage temperature monitoring.

Single-cage precision

Individual animal ID and temperature tracked right inside the home cage. One reader per cage keeps data clean and attribution unambiguous for focused studies.

Plug-and-play USB

No dedicated controller or server required. Connect to any lab PC via USB, open the Data Collector software, and start logging in minutes.

Flexible antenna options

Choose a 3″ round or 2″×5″ rectangular antenna; mount magnetically or with the included clip to match virtually any cage type or rack configuration.

Scalable up to 8 readers

Grow from a single cage to eight connected readers on one workstation. Add more readers at $300 each as your study design expands — no software upgrade required.

±0.1°C accuracy

UID UCT-2112 temperature-sensing microchips deliver lab-grade readings within ±0.1°C across the 30–46°C physiological range, tied directly to individual animal IDs.

Non-invasive & IACUC-aligned

Continuous monitoring without handling supports the Refinement principle. Passive transponders and automated logging reduce stress events and simplify IACUC welfare documentation.

Pricing & Kits

Transparent pricing. No hidden fees.

Everything you need to start monitoring on day one, with room to grow at your own pace.

AnyCage Lite 4-Cage Reader Kit

$1,995
One-time purchase — software included
Kit includes
  • 4× AnyCage Lite Readers with 3″ Round Antennas
  • 4× (2″×5″) Rectangular Antennas
  • USB 4-Port Hub
  • Pack of 24 UID temperature transponders (sterile cannula)
  • Pistol Grip Microchip Injector
  • Data Collector Software for AnyCage Lite

Supports up to eight readers per workstation — expand your study by adding components individually.

Request Quote

Additional Components

Add readers and accessories as needed
Individual items
  • Additional AnyCage Lite Reader $300 each
  • Replacement Round Antenna $50
  • Replacement Rectangular Antenna $50
  • Magnetic Mounts (pack of 20) $45
  • 4-Port Cradle $150
  • Antenna Cable $19
View Full Shop
Product Comparison

Choose the right system for your study

All three platforms share the same UID UCT-2112 microchip ecosystem. Your choice depends on study size, data needs, and infrastructure.

Feature
You are viewing AnyCage Lite Individual cages · Small studies
AnyCage+ Rack-scale · Large cohorts
Mouse Matrix Activity and physiological data
Monitors Temperature Temperature Temperature + Activity + Location
Ideal for Single cages, small studies Rack-scale, large cohorts Detailed activity and physiological data
Scalability Up to 8 cages Up to 96 cages per system Up to 48 per system
Animals tracked Individual or group-housed up to 5/cage Individual or group-housed up to 5/cage Individual or group-housed up to 5/cage
Monitoring rate Continuous (if connected to PC) Continuous Continuous w/ ea. zone scanned every 100–250 ms
Mount Magnetic or clip mount Magnetic or clip mount Plate under cage
Connectivity USB + PC Controller, Hubs, Readers Controller, PoE switch, PC
Temp accuracy ±0.1°C (30–46°C) ±0.1°C (30–46°C) ±0.1°C (30–46°C)
Microchip UID UCT-2112 UID UCT-2112 UID UCT-2112
Software VivoTraq Mouse Matrix

Need rack-scale coverage? See AnyCage+ → · Need activity + temperature? See Mouse Matrix → · Compare all →

Get Started Today

Start monitoring in a single afternoon.

Plug in, open the software, and log your first temperature readings the same day the kit arrives. No installation appointments. No server configuration. No waiting.